INSPECTION AND REMOVAL CRITERIA ASME B30.26-2 ADJUSTABLE HARDWARE 26-2.8.4 Removal Criteria • Missing or illegible identi cation. • Indications of heat damage, including weld spatter or arc strikes. • Excessive pitting or corrosion. • Bent, twisted, distorted stretched, elongated, cracked, or broken load-bearing components. • Excessive nicks or gouges. • A 10% reduction of the original or catalog dimension at any point. • Excessive thread damage or wear. • Evidence of unauthorized welding or modi cation. • For swivel hoist rings, lack of the ability to freely rotate or pivot. • Other conditions, including visible damage, that cause doubt as to continued use. ASME B30.26-3 COMPRESSION HARDWARE 26-3.8.4 Removal Criteria • Missing or illegible identi cation. • Indications of heat damage including weld spatter or arc strikes. • Excessive pitting or corrosion. • Bent, twisted, distorted, stretched, elongated, cracked, or broken components. • Excessive nicks or gouges. • A 10% reduction of the original or catalog dimension at any point. • Evidence of unauthorized welding. • Unauthorized replacement components. • Insuf cient number of wire rope clips. • Improperly tightened wire rope clips. • Indications of damaged wire rope. • Indications of wire rope slippage. • Improper assembly or other conditions, including visible damage, that cause doubt as to continued use. Sharrow Lifting Products 88 (651) 489-1341 • (800) 565-8821