Skip to content

Summit Lifting Devices · a division of Sharrow Lifting Products

Build-a-Triangle-Beam

A beam cut from flat steel plate, with a hole at the top for the hook and holes along the bottom for the load. Set the spacing and the drawing follows your numbers — including an off-centre pick when the load will not balance.

Your specification

0.25 to 20 tons, including the rigging below the beam

= 2,000 lb, which is what gets stencilled on the beam.

12" to 60" centre to centre of the two outer holes — the dimension a rigger measures

stocked sizes

Outer two sit at the corners; any extras spread evenly between them

Slides the top hole off centre so it sits over the load's centre of gravity. 0 is centred, and it goes 9.6" either way at this spacing.

Reference drawing

WLL 2,000 LBS24" pick spacing11.53" overall100° INCLUDED ANGLE — PICK SPACING, HEIGHT AND HOLE POSITIONS TO SCALEPLATE THICKNESS NOT SHOWN AND NOT WLL-DRIVEN — HOLE SIZES ILLUSTRATIVE — SIZED BY OUR ENGINEER, NOT BY THIS PAGE
24" is a size we already stock as a standard part, with a part number, a weight and a published headroom — none of which a drawing from this page can give you. Look at the stocked triangular beams before asking us to build one.

Your beam: 1-ton WLL (2,000 lb), 24" pick spacing, 11.53" overall height, plate construction, 3" x 5" oblong hole (slot) top pick point, 2 lower pick points, leg lengths 19.48" / 19.48"

Built to ASME BTH-1, the standard for below-the-hook lifting devices. Every beam is signed off by our engineer against your actual lift before anything is cut, and the finished beam ships with its load test and certificate. A triangular beam carries its load through the steel around the holes, so the thickness, the hole sizes and the edge distances come from our engineer, not from this page. Everything drawn above — pick spacing, height and hole positions — is to your numbers.

Quote this beamSends the drawing's full spec to our sales desk. No obligation.

Start here first

If your spacing is 12, 24 or 36 inches, buy the stocked one

We carry the standard triangular plate beams in three spacings and seven capacities, from 500 lb to 80,000 lb. A stocked part has a part number, a published headroom, a known weight and no engineering lead time. This page cannot give you any of those, so it is worth thirty seconds to check the catalogue before you ask us to build one.

When a custom one is the right answer

Three things the catalogue cannot do

These are the cases worth building for. Everything else is usually a stocked part in disguise.

A spacing that is not 12, 24 or 36

Lugs on a weldment, lifting eyes on a casting, a fixture that was never built around a catalogue part. The holes go where your load already has them.

A load that will not balance

Move the top hole off centre and it sits over the real centre of gravity, so the load comes up level instead of hanging crooked. No catalogue part offers this.

More than two lower points

Up to nine holes along the bottom edge, so one beam covers several loads, or spreads a long one across more than two attachment points.

How we quote one

The drawing is yours, the steel is ours

Pick spacing, overall height and hole positions on the drawing are exactly what you typed, measured between things you can put a tape on. What it is made from is the part we work out: a triangular beam carries its load through the steel around the holes, so plate thickness, hole sizes and edge distances are an engineer's job and there is no honest way to read them off a web page.

  • Flat plate, round or slotted top pick point
  • Quarter ton to forty tons, 12" to 60" pick spacing
  • Two to nine lower pick points, 3" apart at the closest
  • Off-centre top hole for an unbalanced load
  • Designed to ASME BTH-1 and signed off before anything is cut
  • Proof load tested, with the certificate in the box

Send us the lift, not just the beam

Tell us what is being lifted and where it picks up, and our engineer sizes the beam against that rather than against a guess.