Skip to content

RUD · Bolt-on lifting points

ACP-TURNADO MAX

Screwed into a tapped hole or through-bolted. The common case, and the one where thread engagement and tightening torque decide whether it holds.

15 part numbers

RUD · boltable

A lifting point is a rated component. We inspect them too.

RUD ACP-TURNADO MAX

RUD · 4 tables

RUD ACP-TURNADO MAX

Transcribed from RUD's USA catalogue. Figures are theirs — tonnes, kilograms and millimetres, with imperial tables where RUD publishes them.

Design factor 4:1

RUD catalogue p50 · 5 part numbers

RUD rates the same part at both 4:1 and 5:1. Use the figure that matches the design factor your application works to.

TypeWLL [t]Weight (kg/unit)A [mm]B [mm]C [mm]D [mm]E [mm]F [mm]G [mm]H [mm]I [mm]K [mm]L [mm]MN [mm]T [mm]Tightening torque [Nm]Order no.
ACP-TURNADO-MAX-12.5t-M3612.57.110632328270456012855168105M36221898007911052
ACP-TURNADO-MAX-16t-M42167.510632328270536013665168113M42241891,5007911053
ACP-TURNADO-MAX-20t-M48201612645451039060.578.516975204139M48272352,0007912630
ACP-TURNADO-MAX-24t-M52 12416.5123.54545103956510817375204–M52242322,0007912631
ACP-TURNADO-MAX-27t-M56 12716.7123.54545103957010817875204–M56242322,0007912632
  • 1 Bolt cannot be replaced.
  • 2 Weight depends on the design.

Design factor 4:1 — vario length

RUD catalogue p50 · 5 part numbers

RUD rates the same part at both 4:1 and 5:1. Use the figure that matches the design factor your application works to.

TypeWLL [t]Weight (kg/unit)A [mm]B [mm]C [mm]D [mm]E [mm]F vario [mm]G [mm]H [mm]I [mm]K [mm]L vario [mm]MN [mm]T [mm]Tightening torque [Nm]Order no.
ACP-TURNADO-MAX-12.5t-M3612.521063232827036–24060128–32355168105–300M36221898008600642
ACP-TURNADO-MAX-16t-M421621063232827042–29060136–37365168113–350M42241891,5008600644
ACP-TURNADO-MAX-20t-M4820212645451039048–311.578.5156.5–42075204126.5–390M48272352,0008600645
ACP-TURNADO-MAX-24t-M52 1242123.545451039552–300–160–40875204–M52242322,0008600647
ACP-TURNADO-MAX-27t-M56 1272123.545451039556–300–164–40875204–M56242322,0008600648
  • 1 Bolt cannot be replaced.
  • 2 Weight depends on the design.

Design factor 5:1 — imperial

RUD catalogue p51 · 3 part numbers

RUD rates the same part at both 4:1 and 5:1. Use the figure that matches the design factor your application works to.

TypeWLL [t]Weight (kg/unit)A [inch]B [inch]C [inch]D [inch]E [inch]F [inch]G [inch]H [inch]IK [inch]L [inch]MN [inch]T [inch]Tightening torque [Nm]Order no.
ACP-TURNADO-MAX-14t-1 1/2″-6UNC147.31063232827048601312 1/4″1681081 1/2″-6UNC7/8"1898007911054
ACP-TURNADO-MAX-16t-1 3/4″-5UNC167.51043232827056601412 5/8″1681171 3/4″-5UNC1″1891,5007911055
ACP-TURNADO-MAX-22t-2"-4.5UNC2214.912645451039063.5791723"2041422"-4.5UNC1 1/8"2352,0007912638
  • 1 Weight depends on the design.

Design factor 5:1 — vario length — imperial

RUD catalogue p51 · 2 part numbers

RUD rates the same part at both 4:1 and 5:1. Use the figure that matches the design factor your application works to.

TypeWLL [t]Weight (kg/unit)A [inch]B [inch]C [inch]D [inch]E [inch]F vario [inch]G [inch]H vario [inch]IK [inch]L vario [inch]MN [inch]T [inch]Tightening torque [Nm]Order no.
ACP-TURNADO-MAX-14t-1 1/2"-6UNC1411063232827048–28760131–3702 1/4"168108–3471 1/2"-6UNC7/8"1898008600643
ACP-TURNADO-MAX-22t-2"-4.5UNC22112645451039051–31179160–4203"204130–3902"-4.5UNC1 1/8"2352,0008600646
  • 1 Weight depends on the design.

Not sure which point the job wants?